Wire and cable guides
Practical guides for choosing and ordering wire and cable. Each one cites the NEC section or table it relies on, so you can check it against the edition your jurisdiction uses. Wire reference charts and calculators
NM-B wire size by circuit: 15 to 60 amp breakers
Which NM-B gauge goes on which breaker, why NM-B uses the 60 C column of NEC Table 310.16, and when to size up for distance or heat.
Published Sep 30, 2026
THHN vs XHHW-2: which building wire to pull
THHN/THWN-2 and XHHW-2 compared: insulation, wet ratings, pulling, conduit fill and where each one belongs, with the NEC tables behind them.
Published Sep 30, 2026
UF-B vs NM-B: indoor cable or underground cable
How UF-B and NM-B differ in build, wet ratings and direct burial, the burial depths from NEC Table 300.5, and the mistakes inspectors flag.
Published Sep 30, 2026
Aluminum vs copper feeders: sizing, cost and terminations
Copper and aluminum feeder sizes side by side from the 75 C column, the 200 A service example, and how to terminate aluminum so it lasts.
Published Sep 30, 2026
Voltage drop: a worked example with NEC Chapter 9, Table 8
Calculate voltage drop by hand for a 150 ft, 16 A run, see how each wire size compares, and learn when moving to 240 V beats buying bigger wire.
Published Sep 30, 2026
How to read the markings on a wire jacket
What each part of a wire legend means: size, stranding, insulation type, voltage, listing, oil and sun ratings, file numbers and footage markers.
Published Sep 30, 2026
Electrical wire color code: what the NEC requires and what is convention
Neutral, ground and hot conductor colors under the NEC, the 120/208 V and 277/480 V conventions, re-marking large conductors and posting rules.
Published Sep 30, 2026
Underground wire: which types to use and how deep to bury them
UF-B, USE-2, URD and conductors in conduit for underground runs, with the minimum cover depths from NEC Table 300.5 and the rules around them.
Published Sep 30, 2026
SOOW vs SJOOW: choosing portable cord
What the letters in SOOW, SJOOW, SEOOW and SJTOW mean, which voltage and duty each suits, and where the NEC says cord cannot go.
Published Sep 30, 2026
Welding cable sizing: amps, lead length and voltage drop
Size welding leads by output current, duty cycle and total circuit length, check the size by voltage drop, and choose Class K or Class M.
Published Sep 30, 2026
How much wire to order: a quick takeoff
Measure the route, add the box and panel allowances from NEC 300.14, multiply by conductors, and decide between a cut and a full spool.
Published Sep 30, 2026
MC vs AC cable: grounding, where each is allowed and fittings
MC and AC armored cable compared under NEC Articles 330 and 320: the grounding path, the AC bonding strip, wet locations, support, fittings and cost.
Published Sep 30, 2026
SER vs SEU cable: service entrance or feeder
SER and SEU compared under NEC Article 338: the bare or insulated neutral, when each may feed a subpanel, and sizing with 310.12 and Table 310.16.
Published Sep 30, 2026
URD vs USE-2: cabled or single conductors for underground runs
URD and USE-2 compared for direct burial: cabled versus single conductors, service laterals, neutral marking and the burial depths in NEC Table 300.5.
Published Sep 30, 2026
GXL vs TXL vs SXL: automotive primary wire compared
SAE J1128 primary wire compared: wall thickness, cross-linked insulation, temperature range, connector seals and where GXL, TXL, SXL and GPT belong.
Published Sep 30, 2026
Welding cable vs battery cable: stranding, jackets and uses
Class K and M welding cable against SAE J1127 battery cable: stranding, flexibility, jackets, ratings, lugs, and why welding cable is not building wire.
Published Sep 30, 2026
PV wire vs USE-2: which conductor goes in a solar array
PV wire and USE-2 compared under NEC 690.31: UL 4703 and 2 kV ratings, sunlight resistance, functionally grounded arrays and the rules by NEC edition.
Published Sep 30, 2026
Cat6 vs Cat6A: bandwidth, 10 gigabit distance, PoE and fire ratings
Cat6 and Cat6A compared: 250 vs 500 MHz, 10GBASE-T at 55 m or 100 m, diameter, shielding, PoE heat in bundles and CMR or CMP listings under the NEC.
Published Sep 30, 2026