How much wire to order: a quick takeoff

Published Sep 30, 2026

Ordering too little wire stops a job; ordering too much leaves you with a partial spool you paid full price for. A quick takeoff before you order gets you close, and knowing when to buy a cut and when to buy a full spool saves money on top of that.

Step 1: measure the route, not the distance

Measure the path the wire actually takes: up the wall, across the ceiling, around beams and down to the device. A run that is 40 ft in a straight line is often 60 ft by the raceway. For a conduit job, measure the conduit, then add each vertical drop.

Step 2: add the extra at each end

NEC 300.14 requires at least 6 in. of free conductor at every box where it is spliced or connected, and where the box opening is less than 8 in. across, at least 3 in. has to reach outside the opening. In practice most electricians leave 8 to 12 in. at a device box and more at a panel, where the conductor has to reach its breaker or lug.

A simple rule: add 2 ft per box and 3 to 6 ft at the panel, more for a large panel where the breaker is far from the entry.

Step 3: multiply by the number of conductors

In conduit, each conductor is a separate wire. A 120/240 V circuit with two hots, a neutral and a ground is four conductors, so a 60 ft conduit run needs 4 x (60 ft + ends) of wire. Order by color:

ConductorColorLength for a 60 ft run with 6 ft of ends
HotBlack66 ft
HotRed66 ft
NeutralWhite66 ft
GroundGreen66 ft

With cable such as NM-B, UF-B or SER, you order the cable once, because the conductors are inside it.

Step 4: add a margin

Add 10 percent to the total for waste, a pull that goes wrong and small changes on site. On long pulls with many bends, add more.

Cut to length or full spool?

SituationBetter choice
One run, one or two colorsCut to length
Several runs of the same size and colorFull spool
Large conductors for a single feederCut to the exact length
Stock for the van or the shopFull spool
A color you rarely useCut to length

Where a product is sold both ways, its page prices the cut and each spool size, so you can compare them before you order. Two things to keep in mind:

  • Cut wire is final sale. It is made to your length and cannot be returned, so measure twice. Uncut spools can be returned under the terms on our returns page.
  • A cut adds a business day to the ship date shown on the product page.

Worked example

A 100 A feeder from a main panel to a subpanel in a detached shop. The conduit route is 85 ft, with 6 ft of ends at the main panel and 4 ft at the subpanel. The feeder is two hots, a neutral and an equipment ground.

  • Length per conductor: 85 + 6 + 4 = 95 ft
  • Add 10 percent: about 105 ft
  • Order: 105 ft each of two hot conductors and the neutral, plus 105 ft of the ground size

The sizes come from the load calculation and NEC Table 310.16; for a comparison of copper and aluminum for a feeder like this, see aluminum vs copper feeders. On a run this long, check voltage drop too with the voltage drop calculator.

Shop by the foot or by the spool

The allowances above are common practice, not code requirements, except where a section of the NEC is cited. Your job conditions and local rules decide the final numbers.