10/3 NM-B Copper Cable

Nonmetallic sheathed cable for dry indoor branch circuits in homes, with a bare ground under a PVC jacket.

Per foot at 25 ft$2.32/ft$2.20/ft on spools or other colors

Choose colors and lengths

Color: Orange

By the foot: cut to your length. Spool: never more per foot than a cut, and returnable uncut unless the line says final sale. Cut to measure: final sale, not returnable.

Skip to Add to cart
    • How to buy Orange, line 1
      $2.32/ft
      Cut to measure: final sale, not returnable.Ships by Wed, Dec 2
Total $0.001 line

Spools ship by Tue, Dec 1. Cut lengths ship by Wed, Dec 2.

For an order placed by 12 PM ET today.

You get a tracking number by email the day it ships.

Free UPS Ground shipping from $1,000 to the lower 48. Below that, a $90 minimum for the first line plus $4.95 for each extra line, or the weight rate if higher. A reel over 150 lb ships by freight, charged in the cart.

$250 minimum order before shipping. Under that, a Minimum order adjustment brings the products to $250, shown before you pay.

Cut to measure wire is final sale: lengths cut by the foot, and spools cut to order from bulk. Other spools and boxes, striped colors included, can come back uncut and unopened within 30 days for a 15 percent restocking fee. Returns policy

Questions about this wire?

Request a callback

Leave your number and a rep calls you back.

At a glance

Ampacity30 A (NEC Table 310.16, 60 C column)
Largest breaker30 A (NEC 240.4(D))
Voltage drop at 100 ft7.44 V, 6.2 percent at 30 A and 120 V single phase
Run length for 3 percent dropAbout 45 ft one way at 30 A and 120 V

Questions about this size

What breaker can 10/3 NM-B Copper Cable go on?
Up to 30 A. NEC 240.4(D) limits 10 AWG copper to 30 A of overcurrent protection whatever the ampacity table says.
How far can I run it before voltage drop is a problem?
At 30 A on a 120 V single phase circuit, about 45 ft one way keeps the drop at 3 percent, the figure an informational note to NEC 210.19(A) suggests for branch circuits. Try other loads in the voltage drop calculator.
Can it be buried directly in the ground?
No, and not in underground conduit either: conduit below grade is a wet location, and NEC 334.12 keeps NM cable out of wet and damp locations. Use UF-B, or wet-rated conductors such as THWN-2 or XHHW-2 in conduit.
Can I buy it by the foot?
Yes, cut to length in whole feet from 25 ft, or on 250, 500, 1,000 ft spools. Cut to measure cable is final sale; uncut spools can be returned within 30 days unless the line says final sale.

Voltage drop calculator

Full specifications

TypeNM-B
Gauge10/3
Conductors3
Conductorcopper
Strandingsolid
Ampacity, NEC Table 310.16, 60 C column30 A
Jacket colorOrange
Sold by the footFrom 25 ft to 5,000 ft, in whole feet
Standard spools250, 500, 1,000 ft
Ships in1 to 2 business days from the order day

Insulation, ratings, listing and weight are confirmed from the manufacturer's sheet with your quote.

Spec sheet on request.

Questions

What is the smallest cut?
25 ft for this product, in whole feet, up to 5,000 ft per row. Each length ships on its own coil.
Can I return cut wire?
No. Cut to measure cable is final sale, and so is a spool cut to order from bulk. Other uncut, unopened spools and boxes, striped colors included, can come back within 30 days for a 15 percent restocking fee.
When does it ship?
The ship dates beside Add to cart are for this product and count business days in Eastern time. You get a tracking number by email the day it ships.
From $/ft