6/3 UF-B Copper Cable
Underground feeder cable for direct burial branch circuits, with conductors molded into a solid PVC jacket. Rated 600 V, 90 C.
- Conductor: stranded copper
- Voltage rating: 600 V
- Temperature rating: 90 C
Per foot at 25 ft$7.32/ft$6.64/ft on spools or other colors
Generic illustrative photo. The actual product may look slightly different.
Spools ship by Tue, Dec 1. Cut lengths ship by Wed, Dec 2.
For an order placed by 12 PM ET today.
You get a tracking number by email the day it ships.
Free UPS Ground shipping from $1,000 to the lower 48. Below that, a $90 minimum for the first line plus $4.95 for each extra line, or the weight rate if higher. A reel over 150 lb ships by freight, charged in the cart.
$250 minimum order before shipping. Under that, a Minimum order adjustment brings the products to $250, shown before you pay.
Cut to measure wire is final sale: lengths cut by the foot, and spools cut to order from bulk. Other spools and boxes, striped colors included, can come back uncut and unopened within 30 days for a 15 percent restocking fee. Returns policy
Questions about this wire?
- Call (509) 303-4726, Mon to Fri, 9am to 5pm Eastern
- Email sales@wirewombat.com
Request a callback
At a glance
| Ampacity | 55 A (NEC Table 310.16, 60 C column) |
|---|---|
| Largest breaker | 55 A, or the next standard size up where NEC 240.4(B) allows |
| Voltage drop at 100 ft | 5.40 V, 2.3 percent at 55 A and 240 V single phase |
| Run length for 3 percent drop | About 130 ft one way at 55 A and 240 V |
Questions about this size
- What breaker can 6/3 UF-B Copper Cable go on?
- Its ampacity is 55 A (60 C column of NEC Table 310.16). The breaker can be that size, or the next standard size up where NEC 240.4(B) allows it. Derate first for more than three current-carrying conductors or high ambient heat.
- How far can I run it before voltage drop is a problem?
- At 55 A on a 240 V single phase circuit, about 130 ft one way keeps the drop at 3 percent, the figure an informational note to NEC 210.19(A) suggests for branch circuits. Try other loads in the voltage drop calculator.
- Can it be buried directly in the ground?
- Yes. It is rated for direct burial; the minimum cover is in NEC Table 300.5 (24 in. for direct burial under the general condition).
- Can I buy it by the foot?
- Yes, cut to length in whole feet from 25 ft, or on 125, 250, 500, 1,000 ft spools. Cut to measure cable is final sale; uncut spools can be returned within 30 days unless the line says final sale.
Full specifications
| Type | UF-B |
|---|---|
| Gauge | 6/3 |
| Conductors | 3 |
| Conductor | copper |
| Stranding | stranded |
| Insulation | PVC |
| Voltage rating | 600 V |
| Temperature rating | 90 C |
| Ampacity, NEC Table 310.16, 60 C column | 55 A |
| Jacket color | Gray |
| Sold by the foot | From 25 ft to 5,000 ft, in whole feet |
| Standard spools | 125, 250, 500, 1,000 ft |
| Ships in | 1 to 2 business days from the order day |
Insulation, ratings, listing and weight are confirmed from the manufacturer's sheet with your quote.
Spec sheet on request.
Questions
- What is the smallest cut?
- 25 ft for this product, in whole feet, up to 5,000 ft per row. Each length ships on its own coil.
- Can I return cut wire?
- No. Cut to measure cable is final sale, and so is a spool cut to order from bulk. Other uncut, unopened spools and boxes, striped colors included, can come back within 30 days for a 15 percent restocking fee.
- When does it ship?
- The ship dates beside Add to cart are for this product and count business days in Eastern time. You get a tracking number by email the day it ships.