250-250-250 kcmil SER Aluminum Cable

Aluminum service entrance cable for the run from the meter to the panel and for subpanel feeds. Rated 600 V, 90 C.

  • Conductor: stranded aluminum
  • Voltage rating: 600 V
  • Temperature rating: 90 C
  • Listing: UL Listed

Per foot at 50 ft$9.73/ft

Product image of SER/SEU aluminum, representative of the family

Choose colors and lengths

Color: Gray

By the foot: cut to your length, final sale. Spool: the factory put-up, returnable uncut, never more per foot than a cut. Cut wire is final sale.

Skip to Add to cart
    • How to buy Gray, line 1
      $9.73/ft
      Ships by Fri, Oct 9
Total $0.001 line

Spools ship by Thu, Oct 8. Cut lengths ship by Fri, Oct 9.

For an order placed now. Orders after 12 PM ET, and on weekends and holidays, count from the next business day.

You get a tracking number by email the day it ships.

Free UPS Ground shipping from $499 to the lower 48. A reel over 150 lb ships by freight, charged in the cart.

Cut wire is final sale. Uncut spools can come back within 30 days for a 15 percent restocking fee. Returns policy

Questions about this wire?

Request a callback

Leave your number and a rep calls you back.

At a glance

Ampacity205 A (NEC Table 310.16, 75 C column)
Largest breaker205 A, or the next standard size up where NEC 240.4(B) allows
Voltage drop at 100 ft3.47 V, 1.4 percent at 205 A and 240 V single phase
Run length for 3 percent dropAbout 205 ft one way at 205 A and 240 V
Outside diameter1.601 in

Questions about this size

What breaker can 250-250-250 kcmil SER Aluminum Cable go on?
Its ampacity is 205 A (75 C column of NEC Table 310.16). The breaker can be that size, or the next standard size up where NEC 240.4(B) allows it. Derate first for more than three current-carrying conductors or high ambient heat.
How far can I run it before voltage drop is a problem?
At 205 A on a 240 V single phase circuit, about 205 ft one way keeps the drop at 3 percent, the figure an informational note to NEC 210.19(A) suggests for branch circuits. Try other loads in the voltage drop calculator.
Can it be buried directly in the ground?
No, and not in underground conduit either: NEC 338.12(A) does not permit SE cable underground, with or without a raceway. Use URD or USE-2, or wet-rated conductors in conduit.
Can I buy it by the foot?
Yes, cut to length in whole feet from 50 ft, or on 500 ft spools. Cut wire is final sale; uncut spools can be returned within 30 days.

Full specifications

TypeSER/SEU aluminum
Gauge250-250-250 kcmil
Conductors3
Conductoraluminum
Strandingstranded
InsulationXLPE
JacketPVC
Voltage rating600 V
Temperature rating90 C
ListingUL Listed
Nominal O.D.1.601 in
Ampacity, NEC Table 310.16, 75 C column205 A
Sold by the footFrom 50 ft to 5,000 ft, in whole feet
Standard spools500 ft
Ships in1 to 2 business days from the order day

Insulation, ratings, listing and weight are confirmed from the manufacturer's sheet with your quote.

Spec sheet on request.

Questions

What is the smallest cut?
50 ft for this product, in whole feet, up to 5,000 ft per row. Each length ships on its own coil.
Can I return cut wire?
No. Cut wire is final sale. Uncut, unopened spools and boxes can come back within 30 days for a 15 percent restocking fee.
When does it ship?
The ship dates beside Add to cart are for this product and count business days in Eastern time. You get a tracking number by email the day it ships.
From $/ft