4 AWG THHN/THWN-2 Stranded Copper Wire

Single conductor building wire for conduit and raceways, with PVC insulation under a nylon jacket that pulls easily. Rated 600 V, 90 C.

  • Conductor: 19-strand copper
  • Voltage rating: 600 V
  • Temperature rating: 90 C
  • Listing: UL Listed, CSA Certified

Per foot at 25 ft$1.89/ft

Product image of THHN/THWN-2, representative of the family

Choose colors and lengths

Colors

Pick one or more. Each color gets its own line; add more lengths to any color.

By the foot: cut to your length, final sale. Spool: the factory put-up, returnable uncut, never more per foot than a cut. Cut wire is final sale.

Skip to Add to cart
  • Black
    • How to buy Black, line 1
      $1.89/ft
      Ships by Fri, Oct 9
Total $0.001 line

Spools ship by Thu, Oct 8. Cut lengths ship by Fri, Oct 9.

For an order placed now. Orders after 12 PM ET, and on weekends and holidays, count from the next business day.

You get a tracking number by email the day it ships.

Free UPS Ground shipping from $499 to the lower 48. A reel over 150 lb ships by freight, charged in the cart.

Cut wire is final sale. Uncut spools can come back within 30 days for a 15 percent restocking fee. Returns policy

Questions about this wire?

Request a callback

Leave your number and a rep calls you back.

At a glance

Ampacity85 A (NEC Table 310.16, 75 C column)
Largest breaker85 A, or the next standard size up where NEC 240.4(B) allows. With 60 C rated terminals (the NEC 110.14(C) default at 100 A or less unless the equipment is marked 75 C) it is 70 A.
Voltage drop at 100 ft5.24 V, 2.2 percent at 85 A and 240 V single phase
Run length for 3 percent dropAbout 135 ft one way at 85 A and 240 V
Outside diameter0.318 in

Questions about this size

What breaker can 4 AWG THHN/THWN-2 Stranded Copper Wire go on?
Its ampacity is 85 A (75 C column of NEC Table 310.16). The breaker can be that size, or the next standard size up where NEC 240.4(B) allows it. Derate first for more than three current-carrying conductors or high ambient heat. With 60 C rated terminals (the NEC 110.14(C) default at 100 A or less unless the equipment is marked 75 C) it is 70 A.
How far can I run it before voltage drop is a problem?
At 85 A on a 240 V single phase circuit, about 135 ft one way keeps the drop at 3 percent, the figure an informational note to NEC 210.19(A) suggests for branch circuits. Try other loads in the voltage drop calculator.
Can it be buried directly in the ground?
No. It is not rated for direct burial. Run it in conduit, which counts as a wet location below grade, or use a direct burial type such as UF-B, USE-2 or URD.
Can I buy it by the foot?
Yes, cut to length in whole feet from 25 ft, or on 500 ft spools. Cut wire is final sale; uncut spools can be returned within 30 days.

Voltage drop calculator

Full specifications

TypeTHHN/THWN-2
Gauge4 AWG
Conductors1
Conductorcopper
Stranding19-strand
InsulationPVC
JacketNylon
Voltage rating600 V
Temperature rating90 C
ListingUL Listed, CSA Certified
Nominal O.D.0.318 in
Ampacity, NEC Table 310.16, 75 C column85 A
Sold by the footFrom 25 ft to 5,000 ft, in whole feet
Standard spools500 ft
Ships in1 to 2 business days from the order day

Insulation, ratings, listing and weight are confirmed from the manufacturer's sheet with your quote.

Spec sheet on request.

Questions

What is the smallest cut?
25 ft for this product, in whole feet, up to 5,000 ft per row. Each length ships on its own coil.
Can I return cut wire?
No. Cut wire is final sale. Uncut, unopened spools and boxes can come back within 30 days for a 15 percent restocking fee.
When does it ship?
The ship dates beside Add to cart are for this product and count business days in Eastern time. You get a tracking number by email the day it ships.
From $/ft